S7-300 Input & output card
SIMATIC S7-300, Analog output SM 332, isolated, 2 AO, U/I;
resolution 11/12 bits, 20-pole, Removing/inserting with active
backplane bus possible
SIMATIC S7-300, Analog output SM 332, isolated, 4 AO, U/I;
diagnostics; resolution 11/12 bits, 20-pole, removing and inserting
possible with active backplane bus
SIMATIC S7-300, Analog output SM 332, isolated, 8 AO, U/I;
diagnostics; resolution 11/12 bits, 40-pole, removing and inserting
possible with active backplane bus
SIMATIC S7, analog output SM 332, isolated, 4 AA; 0/4 to 20 mA,
20-pole, for signals from the hazardous area, diagnostics-capable,
PTB tested
SIMATIC S7-300, Analog output SM 332, isolated by channel, 4 AI,
Resolution 16 bit, 0-10 V, 1-5 V, +/-10 V, +/-20 mA, 0/4-20mA, 20-
pole, suitable for isochronous mode improved bus cycle times for the
isochronous mode
SIMATIC S7-300, Analog input SM 331, Isolated 8 AI, resolution 13
bits U/I/resistor/Pt100, NI100, NI1000, LG-NI1000, PTC/KTY, 66 ms
conversion time; 1x 40-pole
SIMATIC S7-300, Analog input SM 331, isolated, 8 AI, resolution 14
bit, 0.052 ms/channel current, Voltage alarm, diagnostics, 1x 20-pole,
suitable for isochronous mode Improved bus cycle time for
isochronous mode
SIMATIC S7-300, Analog input SM 331, isolated, 2 AI, Resolution
9/12/14 bits, U/I/thermocouple/resistor, alarm, diagnostics, 1x 20-
pole, Removing/inserting with active backplane bus
SIMATIC S7-300, Analog input SM 331, isolated, 8 AI, Resolution
9/12/14 bits, U/I/thermocouple/resistor, alarm, diagnostics, 1x 20-
pole Removing/inserting with active backplane bus
SIMATIC S7-300, Analog input SM 331, isolated, 8 AI; +/-5/10V, 1-5
V, +/-20 mA, 0/4 to 20 mA, 16 bit (55ms), Single rooting (50 V
COM.), 1x 40-pole
SIMATIC S7-300, Analog input SM 331, isolated, 8 AI; +/-5/10V, 1-5
V, +/-20 mA, 0/4 to 20 mA, 16 bit, Single rooting (60 V COM.), 4-
channel operation: 10 ms, 8-channel operation: 23-95ms, 1x 40-pole
SIMATIC S7-300, Analog input SM 331, single channel Isolated 250
V AC, 6 AI thermocouples Type B, E, J, K, L, N, R, S, T Voltage: +/-
25MV to +/-1V 16 bit, 50ms, 1x 40-pole
SIMATIC S7-300, Analog input SM 331, isolated, 2/3/4-wire, 8 AI,
Resistor, Pt100/200/1000 NI100/120/200/500/1000, CU10,
characteristics according to GOST 16 (internal 24) bit, 50ms, 1x 40-
pole
SIMATIC S7-300, Analog input SM 331, isolated, 8 AI thermocouples
Type B, E, J, K, L, N, R, S, T TXK/TXK (L) according to GOST 16 bit,
50ms, 1x 40-pole
SIMATIC S7, analog input SM 331, isolated, 4 AE; 0/4 to 20 mA, 1 x
20-pole, for signals from the hazardous area, diagnostics-capable,
PTB tested
SIMATIC S7, analog input SM 331, isolated, 8 AI thermocouples/4 AI
Pt100, for signals from the hazardous area, diagnostics-capable,
PTB tested 1 x 20-pole
SIMATIC S7, Analog input SM 336, 6 AI; 15 bit; fail-safe analog
inputs for SIMATIC Safety, with HART support, up to Category 4 (EN
954-1)/ SIL3 (IEC61508)/PLE (ISO13849), 1x 20-pole
SIMATIC S7-300, Digital output SM 322, isolated, 8 DO, 24 V DC,
2A, 1x 20-pole
SIMATIC S7-300, Digital output SM 322, isolated, 16 DO, 24 V DC,
0.5A, 1x 20-pole, Total current 4 A/group (8 A/module)
SIMATIC S7-300, Digital output SM 322 High Speed, isolated, 16
DO, 24 V DC, 0.5A, 1x 20-pole
SIMATIC S7-300, Digital output SM 322, isolated, 32 DO, 24 V DC,
0.5A, 1x 40-pole, Total current 4 A/group (16 A/module)
SIMATIC S7-300 digital output SM 322, Isolated in groups of 16,
64DO, 24 V DC, 0.3A sink output Total current 2 A/group, 8
A/module Terminal blocks 6ES7392-1.N00-0AA0 and cable
6ES7392-4...0-0AA0 required
SIMATIC S7-300 digital output SM 322, Isolated in groups of 16,
64DO, 24 V DC, 0.3A source output Total current 2 A/group, 8
A/module Terminal blocks 6ES7392-1.N00-0AA0 and cable
6ES7392-4...0-0AA0 required
SIMATIC S7-300, Digital output SM 322, isolated, 8 DO, 48-125 V
DC, 1.5A, 1x 20-pole
SIMATIC S7-300, Digital output SM 322, isolated, 8 DO, 120/230 V
AC, 1 A, 1x 20-pole
SIMATIC S7-300 digital output SM 322, Isolated in groups of 16,
64DO, 24 V DC, 0.3A sink output Total current 2 A/group, 8
A/module Terminal blocks 6ES7392-1.N00-0AA0 and cable
6ES7392-4...0-0AA0 required
SIMATIC S7-300, Digital output SM 322, isolated, 32 DO, 120 V/230
V AC, 1 A, double-width, 2x 20-pole
SIMATIC S7-300, Digital output SM 322, isolated, 8 DO (relay), 1x
20-pole, 24 V DC, 2 A or 230 V AC, 2A
SIMATIC S7-300, Digital output SM 322, isolated, 8 DO (relay), 1x
40-pole, 24 V DC, 5 A or 230 V AC, 5 A, connectors with springloaded terminal can be used as of 6ES7392-1BM01-0AA0
SIMATIC S7-300, Digital output SM 322, Isolated 16 DO, relay
contacts, 1x 20-pole
SIMATIC S7-300, Digital output SM 322, isolated, 8 DO, 120/230 V
AC, 2A, with single rooting/channel and selectable failure mode, 1x
40-pole
SIMATIC S7-300, Digital output SM 322, isolated, 16 DO (solid-state
relay), 24-48 V AC/DC; 0.5 A with single rooting, 1x 40-pole
SIMATIC S7-300, Digital output SM 322, isolated, 8 DO (relay), 1x
40-pole, 24 V DC, 120-230 V AC, 5 A with RC filter overvoltage
protection
SIMATIC S7, digital output SM 322, isolated, 4 DO, 15 V / 20 mA 1 x
20-pole, for signals from the hazardous area, diagnostics-capable,
PTB tested
SIMATIC S7-300, Digital output SM 322, isolated, 8 DO, 24 V DC,
0.5A (1x 8 DO), Short-circuit protection diagnostics, 1x 20-pole
IMATIC S7, digital output SM 326, F-DO10x 24 V DC/2A PP, failsafe digital output for SIMATIC S7F systems, with diagnostic alarm,
LVV, up to Category 4 (EN 954-1)/ SIL3 (IEC61508)/PLE
(ISO13849), 1x 40-pole
IMATIC S7, Digital output SM 326, F-DO 8x24 V DC/2A PM failsafe digital output Switching to P-M potential up to Category 4 (EN
954-1)/ SIL3 (IEC61508)/PLE (ISO13849), 1x 40-pole
SIMATIC S7-300, Digital module SM 323, isolated, 8DI and 8DO, 24
V DC, 0.5 A Total current 2A, 1x 20-pole
SIMATIC S7-300, Digital module SM 323, isolated, 16 DI and 16 DO,
24 V DC, 0.5 A, Total current 4A, 1x 40-pole
SIMATIC S7-300, Digital module SM 327, isolated, 8DI and 8DX, 24
V DC, 0.5 A 1x 20-pole; 8DX by individual channels Can be
parameterized as DI or DO
SIMATIC S7-300, Digital input SM 321, isolated, 16 DI, 24 V DC, 1x
20-pole
SIMATIC S7-300, Digital module SM 323, isolated, 8DI and 8DO, 24
V DC, 0.5 A Total current 2A, 1x 20-pole
SIMATIC S7-300, Digital input SM 321, isolated, 16 DI, 24 V DC, 1x
20-pole, 0.05 ms input delay
SIMATIC S7-300, Digital input SM 321, Isolated 32 DI, 24 V DC, 1x
40-pole
SIMATIC S7-300 digital input SM 321, Isolated in groups of 16, 64
DI, 24 V DC, 3ms, Sink/source input Terminal blocks 6ES7392-
1.N00-0AA0 and cable 6ES7392-4...0-0AA0 required
SIMATIC S7-300, Digital input SM 321, isolated, 16 DI, 24-48 V
AC/DC with single rooting, 1x 40-pole
SIMATIC S7-300, Digital input SM 321, isolated, 16 DI, 48-125 V DC,
1x 20-pole
SIMATIC S7-300, Digital input SM 321, isolated, 32 DI, 120 V AC, 1x
40-pole
SIMATIC S7-300, Digital input SM 321, isolated, 8 DI, 120 V/230 V
AC, 1x 20-pole
SIMATIC S7-300, Digital input SM 321, Isolated 16 DI, 120/230 V
AC, 1x 20-pole
SIMATIC S7-300, Digital input SM 321, isolated, 16 DI; 24 V DC, 1x
20-pole, process interrupt, diagnostics, suitable for isochronous
mode
SIMATIC S7, digital input SM 321, isolated, 4 DI; 24 V DC,
NAMUR/DIN 19234, for signals from the hazardous area,
diagnostics-capable, PTB tested
SIMATIC S7, Digital input SM 326, 8 DI; 24 V DC, NAMUR, fail-safe
NAMUR input for SIMATIC S7 F-systems, up to Category 4 (EN 954-
1)/ SIL3 (IEC61508)/PLE (ISO13849), 1x 40-pole
SIMATIC S7-300, Simulator module SM 374, for simulation of 16
inputs or 16 outputs or 8 inputs and 8 outputs 16 switches, 16 LEDs
SIMATIC S7-300, dummy module DM 370, Dummy module Use for
module replacement